21  2012 . 12:41:26 GMT+04:00

Configuration summary
---------------------------

Server name.....................upr
Adaptec Storage Manager agent...5.30.00 (17509)
Adaptec Storage Manager console.5.30.00 (17509)
Number of controllers...........1
Operating system................Windows

Configuration information for controller 1
-------------------------------------------------------
Type............................Controller
Model...........................Adaptec 5805
Controller number...............1
Physical slot...................3
Installed memory size...........512 MB
Serial number...................8B131032AA4
Boot ROM........................5.2-0 (15728)
Firmware........................5.2-0 (15728)
Device driver...................5.2-0 (15728)
Controller status...............Optimal
Battery status..................Optimal
Battery temperature.............Normal
Battery charge amount (%).......100
Estimated charge remaining......3 days, 1 hours, 52 minutes
Background consistency check....Disabled
Copy back.......................Disabled
Controller temperature..........Normal (78C / 172F)
Default logical drive task priorityHigh
Number of logical devices.......1
Number of hot-spare drives......0
Number of ready drives..........0
Phy 0...........................3.00 Gb/s
Phy 1...........................3.00 Gb/s
Phy 2...........................3.00 Gb/s
Phy 3...........................3.00 Gb/s
Phy 4...........................3.00 Gb/s
Phy 5...........................3.00 Gb/s
Phy 6...........................3.00 Gb/s
Phy 7...........................3.00 Gb/s

Logical device..................0
Logical device name.............
RAID level......................10
Data space......................273,438 GB
Parity space....................273,438 GB
Date created....................10/28/2008
Stripe size.....................256K
Interface type..................Serial attached SCSI
State...........................Optimal
Additional details..............Quick initialized
Read-cache mode.................Enabled
Write-cache mode................Enabled (write-back)
Write-cache setting.............Enabled (write-back)
Partitioned.....................Yes
Protected by hot spare..........No
Bootable........................Yes
Bad stripes.....................No
Group 0, segment 0..............Present: controller 1, connector 0, device 0, S/N BJL0P8501YRT
Group 0, segment 1..............Present: controller 1, connector 0, device 1, S/N BJL0P8501YS3
Group 1, segment 0..............Present: controller 1, connector 0, device 2, S/N BJL0P8501YR4
Group 1, segment 1..............Present: controller 1, connector 0, device 3, S/N BJL0P8501YNW
Group 2, segment 0..............Present: controller 1, connector 1, device 0, S/N BJL0P8501YPR
Group 2, segment 1..............Present: controller 1, connector 1, device 1, S/N BJL0P8501YS2
Group 3, segment 0..............Present: controller 1, connector 1, device 2, S/N BJL0P8501YRK
Group 3, segment 1..............Present: controller 1, connector 1, device 3, S/N BJL0P850215R

Serial attached SCSI
-----------------------
Type............................Disk drive
Vendor..........................FUJITSU
Model...........................MBA3073RC
Serial number...................BJL0P8501YRT
Firmware level..................0103
Reported channel................0
Reported SCSI device ID.........0
World-wide name.................500000E01B4CAC11
Interface type..................Serial attached SCSI
Size............................68,492 GB
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................0
S.M.A.R.T. warnings.............0
Phy 0...........................3.00 Gb/s
Phy 1...........................No device attached

Type............................Disk drive
Vendor..........................FUJITSU
Model...........................MBA3073RC
Serial number...................BJL0P8501YS3
Firmware level..................0103
Reported channel................0
Reported SCSI device ID.........1
World-wide name.................500000E01B4CBC31
Interface type..................Serial attached SCSI
Size............................68,492 GB
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................0
S.M.A.R.T. warnings.............0
Phy 0...........................3.00 Gb/s
Phy 1...........................No device attached

Type............................Disk drive
Vendor..........................FUJITSU
Model...........................MBA3073RC
Serial number...................BJL0P8501YR4
Firmware level..................0103
Reported channel................0
Reported SCSI device ID.........2
World-wide name.................500000E01B4C7C81
Interface type..................Serial attached SCSI
Size............................68,492 GB
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................0
S.M.A.R.T. warnings.............0
Phy 0...........................3.00 Gb/s
Phy 1...........................No device attached

Type............................Disk drive
Vendor..........................FUJITSU
Model...........................MBA3073RC
Serial number...................BJL0P8501YNW
Firmware level..................0103
Reported channel................0
Reported SCSI device ID.........3
World-wide name.................500000E01B4BFD21
Interface type..................Serial attached SCSI
Size............................68,492 GB
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................0
S.M.A.R.T. warnings.............0
Phy 0...........................3.00 Gb/s
Phy 1...........................No device attached

Type............................Disk drive
Vendor..........................FUJITSU
Model...........................MBA3073RC
Serial number...................BJL0P8501YPR
Firmware level..................0103
Reported channel................0
Reported SCSI device ID.........4
World-wide name.................500000E01B4C7861
Interface type..................Serial attached SCSI
Size............................68,492 GB
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................16
Parity errors...................0
Link failures...................0
Aborted commands................0
S.M.A.R.T. warnings.............0
Phy 0...........................3.00 Gb/s
Phy 1...........................No device attached

Type............................Disk drive
Vendor..........................FUJITSU
Model...........................MBA3073RC
Serial number...................BJL0P8501YS2
Firmware level..................0103
Reported channel................0
Reported SCSI device ID.........5
World-wide name.................500000E01B4CBAD1
Interface type..................Serial attached SCSI
Size............................68,492 GB
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................0
S.M.A.R.T. warnings.............0
Phy 0...........................3.00 Gb/s
Phy 1...........................No device attached

Type............................Disk drive
Vendor..........................FUJITSU
Model...........................MBA3073RC
Serial number...................BJL0P8501YRK
Firmware level..................0103
Reported channel................0
Reported SCSI device ID.........6
World-wide name.................500000E01B4CA011
Interface type..................Serial attached SCSI
Size............................68,492 GB
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................0
S.M.A.R.T. warnings.............0
Phy 0...........................3.00 Gb/s
Phy 1...........................No device attached

Type............................Disk drive
Vendor..........................FUJITSU
Model...........................MBA3073RC
Serial number...................BJL0P850215R
Firmware level..................0103
Reported channel................0
Reported SCSI device ID.........7
World-wide name.................500000E01B520F11
Interface type..................Serial attached SCSI
Size............................68,492 GB
Negotiated transfer speed.......3.00 Gb/s
State...........................Optimal
S.M.A.R.T. error................No
Write-cache mode................Write back
Hardware errors.................0
Medium errors...................0
Parity errors...................0
Link failures...................0
Aborted commands................0
S.M.A.R.T. warnings.............0
Phy 0...........................3.00 Gb/s
Phy 1...........................No device attached


End of the configuration information for controller 1
-------------------------------------------------------